Approvals |
CE, UL, CSA |
Compliance with standards |
IEC-ENC60947-1, IEC-EN60947-5-1 |
Compliance with standards |
IEC-EN60204-1,UNI EN ISO 13849-1,UNI EN ISO 13851 |
Compliance to directives |
2014/35/EU, 2014/30/EU, RoHS 2011/65/EU |
Housing material |
PA Polyammide V0 (UL94) |
Operating temperature |
-25° ÷ +60°C UL:+40°C |
Storage temperature |
-30° ÷ +70°C |
Ambient humidity range |
R.H. <95% non condensing |
Pollution degree |
2 |
Protection degree |
IP20 (IEC-EN60529) |
Power supply |
24V DC +/-10%, 24V AC -15% / +10%, 50÷60Hz class 2 |
Assembly |
DIN rail mounting (EN 50022) |
Overvoltage category |
III |
Short circuit protection |
Internal PTC |
Rated insulation voltage |
Ui 690V - Uimp 4KV (IEC-EN60947-1) |
Inputs: number of safety channels |
2 |
Inputs: safety contact inputs |
S11-S12 and S21-S22 |
Inputs: loop resistance |
Max 30 Kohm (eq.2500m - 1,5mm2 - Cu) |
Input current |
Typical 30mA |
NO safety ouputs |
2 |
NC auxiliary output |
1 |
PNP auxiliary output |
1 |
UL508 electrical category |
Pilot duty B300 / R300 |
AC Performances - single output |
AC1: 250V-6A / 2000VA - AC15: 230V-3A |
DC Performances - single output |
DC1: 24V-6A / 144VA - DC13: 24V-2.5A |
Mechanical life |
>10000000 operations |
Electrical life cat.AC1 (360 s/h) |
100000 operations |
Safety parameters - Performance level / category |
PL e / Category 4 (ISO 13849-1) |
Safery parameters |
PFHd [1/h] 1.35exp(-10) / MTTFd [a] 422.1 |
Safety parameters |
DCavg 99% |
Safety parameters |
B= 5exp(-2) / Bd= 2exp(-2) |
Warranty period |
18 months |